Description:
|
ccasGrpCfgType OBJECT-TYPE
SYNTAX INTEGER {
emWinkStart (1),
emWinkStartFgd (2),
emImmedStart (3),
emDelayDial (4),
fxsLoopStart (5),
fxsGroundStart (6),
sasLoopStart (7),
sasGroundStart (8),
r2Analog (9),
r2Digital (10),
r2Pulse (11),
p7 (12),
fxoLoopStart (13),
fxoGroundStart (14),
fgdOS (15),
nullSignaling (16),
r1Itu (17),
r1Modified (18),
r1Turkey (19),
fgdEANA (20)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Signaling type of the DS0 group.
emWinkStart - CAS E&M Wink Start.
emWinkStartFgd - CAS E&M Wink Start with Feature
group D.
emImmedStart - CAS E&M Immediate Start.
emDelayDial - CAS E&M Delay Dial.
fxsLoopStart - CAS FXS Loop Start.
fxsGroundStart - CAS FXS Ground Start.
sasLoopStart - CAS SAS Loop Start.
sasGroundStart - CAS SAS Ground Start.
r2Analog - R2 ITU Q411.
r2Digital - R2 ITU Q421.
r2Pulse - R2 ITU Supplement 7.
p7 - P7 switch.
fgdOS - Bellcore Feature Group D :
Operator Services Signaling
nullSignaling - 64k clear channel
r1Itu - R1 ITU.
r1Modified - R1 Modified.
r1Turkey - R1 Turkey.
fgdEANA - FGD Exchange Access North American.
"
REFERENCE
"EIA/TIA-464B, chapter 6.2.1.1 Signaling Interface Types.
ITU-T Q411 - Specifications of signalling system R2 line
signalling, analogue version.
ITU-T Q421 - Specifications of signalling system R2 line
signalling, digital version.
ITU-T R2 Supplement 7 - Specifications of signalling system
R2 line signalling, pulsed version.
Bellcore, TR-NPL-000258 - Feature Group D
section 3.4 for Exchange Access North American
section 3.6 for Operator Services Signaling"
DEFVAL { emWinkStart }
|
|