Description:
|
sysTrafficMonitorHighWaterMark OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the high watermark for the switching
bus traffic in percentage. Syslog messages will be
generated if the switching bus traffic goes over
this object value during the polling interval.
Setting this object value to 100 would mean no
syslog message would be generated. For systems
with 3 switching buses, high watermark and syslog
will be for each switching bus."
DEFVAL { 100 }
|
|