Description:
|
smartGenHubMgmtIfType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
regular1822(2),
hdh1822(3),
ddn-x25(4),
rfc877-x25(5),
ethernet-csmacd(6),
iso88023-csmacd(7),
iso88024-tokenBus(8),
iso88025-tokenRing(9),
iso88026-man(10),
starLan(11),
proteon-10MBit(12),
proteon-80MBit(13),
hyperchannel(14),
fddi(15),
lapb(16),
sdlc(17),
t1-carrier(18),
cept(19),
basicIsdn(20),
primaryIsdn(21),
propPointToPointSerial(22), -- proprietary serial
ppp(23),
softwareLoopback(24),
eon(25), -- CLNP over IP
ethernet-3Mbit(26),
nsip(27), -- XNS over IP
slip(28), -- generic SLIP
ultra(29), -- ULTRA technologies
ds3(30), -- T-3
sip(31), -- SMDS
frameRelay(32), -- DTE only
rs232(33),
para(34), -- parallel-port
arcnet(35), -- arcnet
arcnetPlus(36), -- arcnet plus
atm(37), -- ATM cells
miox25(38),
sonet(39), -- SONET or SDH
x25ple(40),
iso88022llc(41),
localTalk(42),
smdsDxi(43),
frameRelayService(44), -- Frame relay DCE
v35(45),
hssi(46),
hippi(47),
modem(48), -- Generic modem
aal5(49), -- AAL5 over ATM
sonetPath(50),
sonetVT(51),
smdsIcip(52), -- SMDS InterCarrier Interface
propVirtual(53), -- proprietary virtual/internal
propMultiplexor(54), -- proprietary multiplexing
ip(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute describes one of the interfaces of agents existing on
modules and their type. Value 'none' defines the lack of an
interface whose type is recognized by the management console.
Any other value defines an interface whose type is recognized by
the management console and may be used as a management channel."
|
|