Description:
|
nbsCmmcPortSupplyVoltsLevel OBJECT-TYPE
SYNTAX INTEGER {notSupported(1), lowAlarm(2), lowWarning(3), ok(4), highWarning(5), highAlarm(6)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether this port has a problem
with the electric voltage across the port.
If this port does not support SFF-8472 Digital Diagnostics,
this value should be notSupported(1).
If Digital Diagnostics indicate SupplyVolts is below the
low Alarm Threshold, this value should be lowAlarm(2).
If Digital Diagnostics indicate SupplyVolts is above the
low Alarm Threshold but below the low Warning threshold,
this value should be lowWarning(3).
If Digital Diagnostics indicate this port is within the
recommended operating range, value is ok(4).
If Digital Diagnostics indicate SupplyVolts is higher than
the high Warning threshold, but has not crossed the Alarm
threshold, this value should be highWarning (5),.
If Digital Diagnostics indicate this port has crossed the
high Alarm threshold, this value should be highAlarm(6).
The related object nbsCmmcPortSupplyVolts indicates what the
current supply voltage is."
DEFVAL {ok}
|
|