Description:
|
colPeakTable OBJECT-TYPE
SYNTAX SEQUENCE OF ColPeakEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute specifies the length of the accounting peak water mark
interval. It is at least one minute and at most 15 minutes long. An
accounting peak water mark within a given accounting interval is
the accounting count which occurred during a peak water mark
interval with the highest traffic. Peak water marks are used to
determine traffic bursts. If no value is provisioned for this attribute
value of 5 minutes is assumed. Peak water mark is only measured if
attribute collectionTimes in Collector/account is provisioned."
|
|