Description:
|
rsInventoryMIB MODULE-IDENTITY
LAST-UPDATED "200108220000Z" -- August 22, 2001
ORGANIZATION "Riverstone Networks, Inc"
CONTACT-INFO "Riverstone Networks
Customer Service
Postal:
Riverstone Networks, Inc
5200 Great America Parkway
Santa Clara CA 95054 USA
PHONE:+1 408.878.6500
EMAIL: nms-eng@riverstonenet.com
WEB: http://www.riverstonenet.com"
DESCRIPTION
"This module defines a schema to do an inventory of an RS system."
REVISION "200108220000Z"
DESCRIPTION
"Change the CLEI object to read-write. Delete fabric and submodule
groups."
REVISION "200106190000Z"
DESCRIPTION
"Comments from review meeting with NMS team. Delete all objects
pertaining to the state of the system. This MIB will focus on the
inventory of the system. The state of the system would be in
another MIB. Get rid of all extra objects. Delete the following
tables: rsInventoryPortTable. Delete the following objects:
rsInventoryChassisType, rsInventoryChassisMaxSlots,
rsInventoryChassisNumModules, rsInventoryModuleType,
rsInventoryModuleNumPorts, rsInventoryModuleState. Change name
from rstone-hardware-mib.txt to rstone-inventory-mib.txt. Delete
textual conventions RSChassisType, RSModuleType, RSModuleState,
RSPortType, RSPortConnectorType. Change the length of
RSModuleServiceString"
REVISION "200106110000Z"
DESCRIPTION
"Comments from Mike MacFaden. Use INTEGER only for enumerations,
otherwise use Integer32. Use OBJECT-IDENTITY instead of
OBJECT-IDENTIFIER? Don't use -1 for enumerations? Add more
comments in REVISION DESCRIPTION.
Comments from Thippana Hongal. Change range of RSMemorySize to
start from 0. Rename the enumerations in RSChassisType. Give an
example of RSModuleServiceString? Rename enumerations for
RSModuleState. Make the ordering of rsChassisMaxSlots and
rsInventoryChassisNumModules consistent with their order in
SEQUENCE RsInventoryChassisEntry. Give an example of
rsInventoryChassisId. Add an object describing the position of
the modules in the chassis?"
REVISION "200106010000Z"
DESCRIPTION
"Comments from Kenshin Sakura. Add IA product line. Stop
using internal names. Make RSModuleType enumerations consistent
like this: <
|
|