Description:

xupsMIB MODULE-IDENTITY
LAST-UPDATED "202005270000Z"
ORGANIZATION "Eaton Corporation"
CONTACT-INFO
"Eaton Power Quality Technical Support (PQTS) group
www.eaton.com/powerxpert
Technical Resource Center phone numbers
United States: 1.800.843.9433 or 919.870.3028
Canada: 1.800.461.9166 ext. 260
All other countries: Call your local service representative."
DESCRIPTION
"Defines Eaton's proprietary PowerMIB for UPS and related device data.
Copyright (C) Exide Electronics 1992-98
Copyright (C) Powerware Corporation 1999-2004
Copyright (C) Eaton Corporation (2005-)."
REVISION "202005270000Z"
DESCRIPTION
"xupsEnvRemoteCommunicationStatus is added, it reports the EMP communication status.
Add a new value in enum xupsOutputStatus for the case the output is powered but no continuity feature."
REVISION "202001230000Z"
DESCRIPTION
"xupsInputTable, xupsOutputTable and xupsBypassTable collection are completed with the phase to phase voltage measure."
REVISION "201909270000Z"
DESCRIPTION
"xupsOutputSource data can monitor the ESS mode."
REVISION "201909120000Z"
DESCRIPTION
"Provide new data that reflects some battery alarm: xupsBatteryFailure, xupsBatteryNotPresent, xupsBatteryAged, xupsBatteryLowCapacity."
REVISION "201909100000Z"
DESCRIPTION
"Change the data xupsBatteryLastReplacedDate to read-only because the card sets it automatically when the battery replacement is detected."
REVISION "201904120000Z"
DESCRIPTION
"Provide the status of the main AC Input in xupsInputStatus.
Provide the status of the AC Output in xupsOutputStatus and a new trap and alarm 'load not protected' in xupsOutputNotProtected."
REVISION "201903050000Z"
DESCRIPTION
"Provide more UPS identification data as xupsIdentPartNumber and xupsIdentSerialNumber.
Provide a collection xupsAgent that contains identification data of the card: xupsAgentManufacturer, xupsAgentModel, xupsAgentSoftwareVersion, xupsAgentPartNumber, xupsAgentSerialNumber"
REVISION "201902190000Z"
DESCRIPTION
"To ensure consistency with the measures done on the UPS, the data following are renamed: xupsInputAverageCurrent to xupsInputTotalCurrent, xupsOutputAverageCurrent to xupsOutputTotalCurrent, xupsBypassAverageCurrent to xupsBypassTotalCurrent."
REVISION "201809120000Z"
DESCRIPTION
"Add new data xupsInputId, xupsInputName, xupsInputCurrentHighPrecision in the table xupsInputTable.
Add new sub collection xupsInputTotal with xupsInputAverageVoltage, xupsInputAverageCurrent, xupsInputTotalWatts, xupsInputTotalVA, xupsInputAveragePowerFactor inside.
Add new data xupsOutputId, xupsOutputName, xupsOutputCurrentHighPrecision, xupsOutputPercentLoad, xupsOutputVA in the table xupsOutputTable.
Add new sub collection xupsOutputTotal with xupsOutputAverageVoltage, xupsOutputAverageCurrent, xupsOutputTotalWatts, xupsOutputTotalVA, xupsOutputAveragePowerFactor inside.
Add new data xupsBypassId, xupsBypassName, xupsBypassCurrentHighPrecision, xupsBypassWatts in the table xupsBypassTable.
Add new sub collection xupsBypassTotal with xupsBypassTotalAverageVoltage, xupsBypassAverageCurrent, xupsBypassTotalWatts, xupsBypassTotalVA, xupsBypassTotalAverageFactor inside."
REVISION "201804230000Z"
DESCRIPTION
"Add new data xupsTestTrap, xupstdTestTrap that will allow to initiate a test trap sent out from the agent to the trap receivers."
REVISION "201211261513Z"
DESCRIPTION
"Add the identifier of measures xupsInputId, xupsOutputId and xupsBypassId, respectively in the table xupsInputTable, xupsOutputTable and xupsBypassTable."
REVISION "201204030000Z"
DESCRIPTION
"Add new data xupsOutputHourlyPowerUsage, xupsOutputCumulativePowerUsage, and xupsOutputCumulativePowerUsageTimer into the collection xupsOutput.
Add new data xupsRecepHourlyPowerUsage, xupsRecepCumulativePowerUsage, and xupsRecepCumulativePowerUsageTimer into the collection xupsRecepTable."
REVISION "201102250000Z"
DESCRIPTION
"Add new data xupsSwitchable"
REVISION "200810020000Z"
DESCRIPTION
"Added new values of batteryDisconnected(6), batteryUnderTest(7), and checkBattery(8) to xupsBatteryAbmStatus."
REVISION "200705030000Z"
DESCRIPTION
"Added new value of pxg(5) to xupsSendTrapType for Power Xpert Gateway implementations."
REVISION "200703130000Z"
DESCRIPTION
"Initial SNMPv2-SMI-compliant Version of PowerMIB.
Incorporates all revisions of the original xups MIB file through Version 3.13 21-May-04."


 