Description:
|
teaPwTDMCfgFramedSigInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object configures the application signaling
interval to use when sending the CAS signaling
in a separate packet stream.
The object's unit is ms and the default value is 5 ms."
DEFVAL {5 }
|
|