Description:
|
lucentPM4FMT1E1ThreshPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold for path code violations on the interface.
A trap is issued when this set threshold is exceeded. PCV
is a frame syncronization bit error in the D4 and E1-noCRC
format interfaces or a CRC error in the ESF (extended super
frame) and E1-CRC interface formats."
|
|