Description:
|
brzaccVLInterferenceMitigationAutomaticScanPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to 900 MHz units, 2.4 GHz units and BNB10.
The period of time, in minutes, to execute automatic channel scanning,
when performing Interference Mitigation.
Range: 0 or 10-10080 minutes.
A value of 0 means periodicity disabled,
Interference Mitigation being performed only one time."
|
|