Description:
|
eoPowerMeasurementCaliber OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1) ,
unknown(2),
actual(3) ,
estimated(4),
static(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies how the usage value reported by
eoPower was obtained:
- unavailable(1): Indicates that the usage is not
available. In such a case, the eoPower value must be 0
for devices that cannot measure or report power this
option can be used.
- unknown(2): Indicates that the way the usage was
determined is unknown. In some cases, entities report
aggregate power on behalf of another device. In such
cases it is not known whether the usage reported is
actual, estimated, or static.
- actual(3): Indicates that the reported usage was
measured by the entity through some hardware or direct
physical means. The usage data reported is not estimated
or static but is the measured consumption rate.
- estimated(4): Indicates that the usage was not
determined by physical measurement. The value is a
derivation based upon the device type, state, and/or
current utilization using some algorithm or heuristic. It
is presumed that the entity's state and current
configuration were used to compute the value.
- static(5): Indicates that the usage was not determined
by physical measurement, algorithm, or derivation. The
usage was reported based upon external tables,
specifications, and/or model information. For example, a
PC Model X draws 200W, while a PC Model Y draws 210W."
|
|